Other characteristics and tolerances
Subscribe to our newsletter
RESIDUAL CURVATURE |
|
Max. distance for a sample 500 mm in length applicable for width > 150 mm |
35 mm |
EDGE CAMBER |
|
Max. edge camber for a measuring length of 1,500 mm applicable for width > 150 mm |
0.5 mm |
DEVIATION FROM THE SHEARING LINE DUE TO INTERNAL STRESSES |
|
Max. measured gap within a strip length of 1,500 mm applicable for width > 500 mm |
1.0 mm |
FLATNESS (WAVE FACTOR) |
|
Max. wave factor applicable for width > 150 mm |
1.5% |
BURR HEIGHT (ONLY FOR SLIT WIDTH) |
|
Max. burr height |
0.025 mm |
The measuring methods for thickness and width are given in the product standards EN 10 107 and IEC 60 404-8-7.
All other measuring methods and definitions are given in EN10 251 and IEC 60 404-9.
The quoted values are in many cases better than those specified in the EN or IEC-Norm.